img
SYSTEM ERROR CODEシステムエラーコード採用情報

2009年以降のErgoline・Soltronシステムエラーコードです。
エラー解除については資格技術者のアドバイスに従って下さい。


E001 Warning: condensate tank full
E002 Warning: exhaustion of condensed water defective
E003 System message: overpressure switch air conditioning system
E004 System message: pressure sensor higher than 25 bar
E005 Warning: temperature fuse body heating
E006 Warning: temperature sensor body air
E010 System message: temperature fuse facial tanner
E011 System message: temperature fuse for canopy
E012 System message: temperature fuse for base
E013 System message: air outlet temperature sensor for canopy
E014 System message: air inlet temperature sensor
E015 System message: temperature sensor air circulation for unit?s cooling
E016 System message: temperature sensor capacitor air conditioning system
E017 System message: temperature sensor air inlet
E018 System message: lamp temperature < room temperature
E019 System message: lamp temperature > room temperature + 30° C / 86° F
E020 System message: filter glass facial tanner (canopy centre and rear)
E021 System message: filter glass facial tanner (canopy in front)
E022 System message: filter glass facial tanner (side section)
E023 System message: filter glass facial tanner (canopy - side section)
E024 System message: filter glass facial tanner (canopy centre, rear, front)
E025 System message: filter glass facial tanner (canopy centre, rear, front and side section)
E027 System message: filter glass facial tanner (canopy rear)
E028 System message: filter glass facial tanner (canopy centre)
E029 Warning message: Timeout inspection of the high pressure units
E030 System message: safety switch acrylic panel canopy (or glass decor canopy Avantgarde)
E031 System message: safety switch acrylic panel base or tank base
E032 System message: safety switch acrylic panel (canopy - side section ? base ? tank - shoulder tanner)
E034 System message: safety switch acrylic panel (canopy ? side section ? base ? tank - shoulder tanner)
E035 System message: safety switch acrylic panel (canopy ? base ? side section or shoulder tanner)
E036 System message: safety switch acrylic panel base or tank base
E037 System message: safety switch acrylic panel canopy or side section
E038 System message: safety switch acrylic panel base or tank base
E039 System message: safety switch acrylic panel shoulder tanner
E040 System message: air flow switch has not turned on
E041 System message: air flow switch has not turned off
E042 Warning: air flow switch has not turned on (increasing rotation speed by 10%)
E050 System message: safety switch front panel front (top)
E052 System message: opening mechanism arm > 45 seconds
E053 System message: filter glass high-pressure units upper body (3-4-5-8-9-10)
E054 System message: filter glass high-pressure units lower body (1-2-6-7)
E055 System message: malfunction high-pressure unit 1(front)
E056 System message: malfunction high-pressure unit 2 (rear)
E057 System message: malfunction high-pressure unit (front)
E058 System message: malfunction high-pressure unit (centre)
E059 System message: malfunction high-pressure unit (rear)
E060 System message: malfunction high-pressure unit (side section)
E061 System message: safety switch acrylic panel and canopy cover
E062 System message: safety switch acrylic panel base and side section
E063 System message: safety switch acrylic panel side section
E064 System message: safety switch cover
E065 System message: safety switch acrylic panel canopy
E070 System message: malfunction high-pressure unit (1) foot (front)
E071 System message: malfunction high-pressure unit (2) foot (centre)
E072 System message: malfunction high-pressure unit (3) foot (rear)
E073 System message: malfunction high-pressure unit (4) foot (side section)
E074 System message: malfunction high-pressure unit (5) legs (front)
E075 System message: malfunction high-pressure unit (6) legs (centre)
E076 System message: malfunction high-pressure unit (7) legs (rear)
E077 System message: malfunction high-pressure unit (8) legs (side section)
E078 System message: malfunction high-pressure unit (9) body (front)
E079 System message: malfunction high-pressure unit (10) body (centre)
E080 System message: malfunction high-pressure unit (11) body (rear)
E081 System message: malfunction high-pressure unit (12) body (side section)
E082 System message: malfunction high-pressure unit (13) upper body (front)
E083 System message: malfunction high-pressure unit (14) upper body (centre)
E084 System message: malfunction high-pressure unit (15) upper body (rear)
E085 System message: malfunction high-pressure unit (16) upper body (side section)
E090 System message: emergency switch-off time exceeded
E091 System message: I2C-Bus transmission error
E092 System message: wiring power error in the safety chain
E095 System message: additional controller
E100 System message: emergency switch-off time exceeded
E101 System message: I2C-Bus transmission error
E102 System message: wiring power error in the safety chain
E103 Warning: malfunction audio unit
E104 System message: chip card error
E105 System message: additional controller
E106 System message: heating controller
E107 System message: controller facial tanner
E108 System message: malfunction rotation speed control 1
E109 System message: malfunction rotation speed control 2
E110 Warning: Aroma / Aqua-Fresh Controller
E111 Warning: Audio amplifier
E112 Warning: channel choice
E113 System message: malfunction real-time clock
E114 System message: malfunction equipment pass / parameter memory
E115 System message: electronic ballasts / lamp ballasts control PCB
E116 System message: high-pressure fan control PCB
E119 System message: malfunction data communication cockpit control
E120 System message: malfunction skin type measurement
E121 System message: calibration required
E122 System message: calibration failed
E123 System message: validation failed
E124 System message: data communication with the sensor defective
E125 Warning: tanning in normal mode
E126 System message: power supply voltage
E128 System message: undervoltage
E130 System message: equipment mistake of the PCB slot
E131 System message: data communication additional controller
E132 System message: start-up inspection of the UV sources
E133 System message: switch function additional controller rotation speed control
E134 System message: malfunction fuse rotation speed
E135 System message: malfunction power supply rotation speed control
E140 System message: malfunction main conductor does not switch on
E141 System message: malfunction main conductor does not switch off
E142 System message: malfunction switch-on cycle main conductor
E143 System message: malfunction difference coin box input
E150 System message: malfunction high-pressure unitsA 1-3
E151 System message: malfunction high-pressure unitsA 4-6
E152 System message: malfunction high-pressure unitsB 7-9
E153 System message: malfunction high-pressure unitsB10-12
E154 System message: malfunction high-pressure unitsC13-15
E155 System message: malfunction high-pressure unitsC16-18
E156 System message: malfunction high-pressure unitsD19-21
E157 System message: malfunction high-pressure unitsD22-24
E158 System message: malfunction high-pressure unitsE25-27
E159 System message: malfunction high-pressure unitsE28-30
E160 em message: malfunction acrylic panel high-pressure units A 1-6
E161 System message: malfunction acrylic panel high-pressure units B 7-12
E162 System message: malfunction acrylic panel high-pressure units C 13-18
E163 System message: malfunction acrylic panel high-pressure units D 19-24
E164 System message: malfunction acrylic panel high-pressure units E 25-30
E165 System message: malfunction high-pressure units 1-3 (left side)
E166 System message: malfunction high-pressure units 5-7 (right side)
E167 System message: malfunction high-pressure unit 4 (left side)
E168 System message: malfunction high-pressure unit 8 (right side)
E170 System message: Power Supply of the fan control input at the main baord is missing
E190 Warning: missing language in the cockpit control
E191 Warning: missing language in the audio controller
E192 System message: Timer mode activated
E200 Warning: malfunction fan electronic component board
E202 System message: error during software update
25b Warning: pressure of air condition above 25 bar
40°C Warning: air input temperature above 40° C / 104° F
50°C Warning: air circulation or lamp temperature above 50 °C / 122° F
DOORWarning: upright tanner?s door open